The paper presents the results of investigation of heat pipes used for thermostabilization of permafrost. Liquid ammonia and alcohol-water mixture were used as working fluids. The lengths of the heat pipes were 1.88 and 6.0 m. The finns were manufactured of aluminium and copper. Three designs of heat pipes were tested with various modifications of the evaporator, namely, a thermosiphon, a heat pipe with a capillary-porous wick, a heat pipe with a screw. The results on the dependence of the transferred heat fluxes and temperature drops along the pipe on the horizontal slopes are given.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Application of heat pipes for freezing grounds


    Additional title:

    Anwendung von Temperaturuebertragungsrohren bei Dauerfrost


    Contributors:


    Publication date :

    1978


    Size :

    5 Seiten, 2 Bilder, 3 Tabellen, 5 Quellen


    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English