A major factor controlling the specific energy of a lead/acid battery is the utilization of active material. If this could be increased, the specific energy would be increased, with a corresponding increase in range of electric vehicles using the lead/acid battery. The main parameters that affect active-material utilization are examined, namely, current density, plate thickness, active-material structure, conductivity of active material and grid, and electrolyte volume and density. Increases in utilization can be achieved by changing all these parameters and examples are given.


    Access

    Access via TIB

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Improving active-material utilization


    Contributors:

    Published in:

    Journal of Power Sources ; 67 , 1-2 ; 105-109


    Publication date :

    1997


    Size :

    5 Seiten, 17 Quellen




    Type of media :

    Article (Journal)


    Type of material :

    Print


    Language :

    English




    Improving active-material utilization

    Bagshaw, N.E. | Online Contents | 1997


    Electro-Osmotic Pumping to Enhance Positive Active Material Utilization

    Dyson, J. I. / Turner, A. D. / Jones, C. P. | British Library Conference Proceedings | 1997


    Improving utilization of steam power

    Engineering Index Backfile | 1950


    Lifeboat capable of improving utilization efficiency

    LI XIANRONG | European Patent Office | 2020