A sensor system which is capable of measuring the effectiveness of an electromagnetic damping system in a System Generated Electromagnetic Pulse (SGEMP) test facility has been designed and applied to a predictable damping configuration. Results show that the system is capable of evaluating the damping of the TM n,1 modes of the facility.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Experimental investigations of the damping of an SGEMP simulation chamber using a single sheet empedance loaded damper


    Additional title:

    Experimentelle Untersuchungen der Daemmung (Abschirmung) einer SGEMP Simulationskammer unter Verwendung eines einzelnen impedanzgeladenen Schirms


    Contributors:
    Seidler, W.A. (author) / Neal, W.R. (author)

    Published in:

    Publication date :

    1977


    Size :

    7 Seiten, 6 Bilder, 1 Tabelle, 10 Quellen



    Type of media :

    Article (Journal)


    Type of material :

    Print


    Language :

    English