Evaporative cooling was applied to a heavy duty diesel engine to investigate the feasibility of this cooling method.Engine test results showed the following benefits of this cooling method: Reduction of the size of theradiator and cooling fan is feasible. The maximum temperature of the combustion chamber wall did not increase, though the coolant temperature rose by 20°C. The fuel consumption could be reduced especially at partial load. Engine warm-up performance was significantly improved.An oil cooler rig test was also conducted to investigate the heat transfer characteristics of the oil cooler with evaporative cooling.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    An Application Study of Evaporative Cooling to Heavy Duty Diesel Engines


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:

    Kongress:

    SAE International Congress and Exposition ; 1987



    Erscheinungsdatum :

    1987-02-01




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    An application study of evaporative cooling to heavy duty diesel engines

    Watanabe,Y. / Ishikawa,H. / Miyahara,M. | Kraftfahrwesen | 1987



    Turbo-compound cooling systems for heavy-duty diesel engines

    Woollenweber,W.E. / Turbo Design,US | Kraftfahrwesen | 1994



    Turbo-Compound Cooling Systems for Heavy-Duty Diesel Engines