In this paper there are considered some differences between the Loop Heat Pipes (LHPs) and the Capillary Pumped Loops (CPLs) performances. There offered the methods of the capillary evaporators reliability function increasing for two-phase systems of the LHP and the CPL type. The reliability increasing of above mentioned systems evaporators is proposed to be done by using of composite wicks and/or thermal electrical coolers. The recommended means could decrease the probability or except completely the “vapor blocade” of absorbing surface of evaporators capillary pumps.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Methods of Increase of the Evaporators Reliability for Loop Heat Pipes and Capillary Pumped Loops


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:
    Kotlyarov, E. Yu. (Autor:in) / Serov, G. P. (Autor:in)

    Kongress:

    International Conference On Environmental Systems ; 1994



    Erscheinungsdatum :

    1994-06-01




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch






    Thermal Model for Sintered Cylindrical Evaporators of Loop Heat Pipes

    Florez, Juan Pablo M. / Mantelli, Marcia B. H. | AIAA | 2016


    Circumferentially Grooved Heat Pipes Applied to a Capillary Pumped Two-Phase Loop

    Bazzo, Edson / Groll, Manfred / Brost, Ortwin et al. | SAE Technical Papers | 1994


    Capillary Limit in a Loop Heat Pipe with Dual Evaporators

    Birur, Gajanana / Ku, Jentung | SAE Technical Papers | 2002