Welded stainless-steel vacuum jackets on cryogenic ducts replaced by plastic foam-insulation jackets that weigh 12 percent less. Foam insulation has 85 percent of insulating ability of stainless-steel jacketing enclosing vacuum of 10 microns of mercury. Foam insulation easier to install than vacuum jacket. Moreover, foam less sensitive to damage and requires minimal maintenance. Resists vibration and expected to have service life of at least 10 years.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Foam Insulation for Cryogenic Flowlines


    Beteiligte:
    Sonju, T. R. (Autor:in) / Carbone, R. L. (Autor:in) / Oves, R. E. (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    1985-06-01



    Medientyp :

    Sonstige


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :


    Leak Tester for Cryogenic Flowlines

    Mortensen, G. D. / Olney, J. N. / Mardesic, J. M. | NTRS | 1983


    Advanced Reusable Foam Cryogenic Insulation

    Taylor, Allan H. / Mcauliffe, P. S. / Sparks, L. L. | NTRS | 1990


    Cryogenic foam insulation - abstracted publications

    Williamson, Frank R. | TIBKAT | 1977


    Reusable High-Temperature/Cryogenic Foam-Insulation System

    Davis, Randall C. / Taylor, Allan H. / Jackson, L. Robert et al. | NTRS | 1987


    Foinaven Fast Track Flowlines

    Taylor, L. H. / Mair, J. | British Library Conference Proceedings | 1996