The report describes the development of three types of ventilator kits for use in OCD fallout shelters: a one-operator bicycle ventilator kit, a two-operator bicycle ventilator kit and a Kearny pump kit. The report also describes the effects of blast tests - peak overpressure 4 psi - on these kits. Operating instructions and military specifications for the kits are included. (Author)
Ventilation Kits
1969
180 pages
Report
Keine Angabe
Englisch
Heating & Cooling Systems , Civil Engineering , Passive Defense Systems , Civil defense systems , Cooling + ventilating equipment , Fallout shelters , Design , Pumps , Exhaust systems , Ducts , Military requirements , Explosion effects , Human engineering , Ventilator kits , Overpressure , Bicycle ventilators
Online Contents | 1994
Emerald Group Publishing | 2000
NTIS | 1995
|British Library Online Contents | 2014
British Library Conference Proceedings | 1993
|