Anode consumption and coating breakdown on a gas well-head X-mas tree with multiple connections for production distribution or injection installed at the Troll Field in the Norwegian North Sea was investigated after 5 years. A comparison was done with a spare tree and one exposed for only 3 to 4 months. The epoxy coating had several blisters, in particular on stainless steel surfaces.
Anode consumption on a subsea X-mas tree
Materials Performance ; 37 , 9 ; 17-19
1998
3 Seiten, 2 Quellen
Aufsatz (Zeitschrift)
Englisch
Testing Technology of Subsea Christmas Tree
Tema Archiv | 2012
|An Update on Subsea Tree Technology
British Library Online Contents | 1997
|