During the conceptual design phase a 20-kHz power distribution system was selected as the reference for the space station. The system is single-phase 400 VRMS, with a sinusoidal wave form. The initial user power level will be 75 kW with growth to 300 kW. The high-frequency system selection was based upon considerations of efficiency, weight, safety, ease of control, interface with computers, and ease of paralleling for growth. Each of these aspects will be discussed as well as the associated trade-offs involved. An advanced development program has been instituted to accelerate the maturation of the high-frequency system. Some technical aspects of the advanced development program will be discussed.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Space station 20-kHz power management and distribution system


    Weitere Titelangaben:

    20-kHz-Energieversorgungs- und -verteilungssystem fuer Raumstationen


    Beteiligte:
    Hansen, I.G. (Autor:in) / Sundberg, G.R. (Autor:in)


    Erscheinungsdatum :

    1986


    Format / Umfang :

    8 Seiten, 10 Bilder, 10 Quellen


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch





    Automation of Space Station module power management and distribution system

    Bechtel, Robert / Weeks, Dave / Walls, Bryan | NTRS | 1990


    Space Station Freedom power management and distribution design status

    Javidi, S. / Gholdston, E. / Stroh, P. | Tema Archiv | 1989



    A power management and distribution concept for space station

    Hackler, I.M. / Robinson, R.L. / Hendrix, B. | Tema Archiv | 1984