This paper presents an experimental investigation of an open loop pulsating heat pipe (OLPHP), where several issues related to its performance were evaluated. Tests were conducted with different working fluids for the OLPHP operating at both vertical and horizontal orientations. The experimental results show that the system presented better performance when operating at horizontal orientation, as lower evaporation section temperatures were achieved. Regarding the working fluids used, the system showed better performance when acetone was used on vertical orientation and methanol on horizontal orientation.
Characteristics of an Open Loop Pulsating Heat Pipe
Sae Technical Papers
International Conference On Environmental Systems ; 2004
2004-07-19
Aufsatz (Konferenz)
Englisch
Performance Evaluation When Using Nanofluids in Loop Heat Pipe and Pulsating Heat Pipe
SAE Technical Papers | 2007
|Pulsating Heat Pipe Automotive Application
SAE Technical Papers | 2020
|Thermal response of a closed loop pulsating heat pipe under a varying gravity force
Tema Archiv | 2014
|Review of Pulsating Heat Pipe Working Fluid Selection
AIAA | 2012
|