A new on-board portable emission measurement system (PEMS) for gaseous emissions has been designed and developed to meet CFR Part 1065 requirements. The new system consists of a heated flame ionization detector (HFID) for the measurement of total hydrocarbon, a heated chemiluminescence detector (HCLD) for the measurement of NOx, and a heated non-dispersive infra-red detector (HNDIR) for the measurement of CO and CO2. The oxygen interference and relative sensitivity of several hydrocarbon components have been optimized for the HFID. The CO2 and H2O quenching effect on the HCLD have been compensated using measured CO2 and H2O concentration. The spectral overlap and molecular interaction of H2O on the HNDIR measurement has also been compensated using an independent H2O concentration measurement. The basic performance of the new on-board emission measurement system has been verified accordingly with CFR part 1065 and all of the performances have met with CFR part 1065 requirement. The new on-board emission measurement system has been also compared with conventional laboratory instrumentation. The results showed good correlation with that of a laboratory system.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Performance Test Results of a New On Board Emission Measurement System Conformed with CFR Part 1065


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:
    Nakamura, Hiroshi (Autor:in) / Khalek, Imad A (Autor:in) / Adachi, Masayuki (Autor:in) / Akard, Michael (Autor:in) / Kihara, Nobutaka (Autor:in) / Porter, Scott (Autor:in)

    Kongress:

    SAE World Congress & Exhibition ; 2007



    Erscheinungsdatum :

    2007-04-16




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch





    2007-01-1326 Performance Test Results of a New On Board Emission Measurement System Conformed with CFR Part 1065

    Nakamura, H. / Akard, M. / Porter, S. et al. | British Library Conference Proceedings | 2007


    Evaluation of an On-board Emission Measurement System conformed to CFR Part 1065 (20065079)

    Aoki, S. / Nakamura, H. / Kihara, N. et al. | British Library Conference Proceedings | 2006


    Evaluation of an On-board Emission Measurement System conformed to CFR Part 1065 (20065079)

    Aoki, S. / Nakamura, H. / Kihara, N. et al. | British Library Conference Proceedings | 2006


    Nr. 1065

    DataCite | 1865

    Freier Zugriff