A connectable/disconectable thermal interface has been developed for the constructable radiator system under development at NASA-Johnson Space Center. A contact heat exchanger approach which involves pressurized clamping of a segmented cylindrical heat exchanger on the outside of a round heat pipe evaporator section was designed, fabricated, and tested. Dry metal-to-metal contact conductance heat transfer is utilized. Test results have indicated excellent contact conductances of up to 8500 w/m2°c (1500 Btu/ft2°F) at 2000 kPa (300 psi) clamping force. The feasibility and fabricability of the design have been demonstrated.
A Contact Conductance Interface for a Space Constructable Heat Pipe Radiator
Sae Technical Papers
Intersociety Conference on Environmental Systems ; 1983
1983-07-11
Aufsatz (Konferenz)
Englisch
A contact conductance interface for a space constructable heat pipe radiator
Tema Archiv | 1983
|A high reliability variable conductance heat pipe space radiator
Tema Archiv | 1978
|Contact Conductance Evaluation for A Full Scale Space Erectable Radiator Pressurized Interface
SAE Technical Papers | 1989
|