Two Disk-Gap-Band model parachute designs were tested in the NASA Langley Transonic Dynamics Tunnel. The purposes of these tests were to determine the drag and static stability coefficients of these two model parachutes at various subsonic Mach numbers in support of the Mars Exploration Rover mission. The two model parachute designs were designated 1.6 Viking and MPF. These model parachute designs were chosen to investigate the tradeoff between drag and static stability. Each of the parachute designs was tested with models fabricated from MIL-C-7020 Type III or F-111 fabric. The reason for testing model parachutes fabricated with different fabrics was to evaluate the effect of fabric permeability on the drag and static stability coefficients. Several improvements over the Viking-era wind tunnel tests were implemented in the testing procedures and data analyses. Among these improvements were corrections for test fixture drag interference and blockage effects, and use of an improved test fixture for measuring static stability coefficients. The 1.6 Viking model parachutes had drag coefficients from 0.440 to 0.539, while the MPF model parachutes had drag coefficients from 0.363 to 0.428. The 1.6 Viking model parachutes had drag coefficients 18 to 22 percent higher than the MPF model parachute for equivalent fabric materials and test conditions. Model parachutes of the same design tested at the same conditions had drag coefficients approximately 11 to 15 percent higher when manufactured from F-111 fabric as compared to those fabricated from MIL-C-7020 Type III fabric. The lower fabric permeability of the F-111 fabric was the source of this difference. The MPF model parachutes had smaller absolute statically stable trim angles of attack as compared to the 1.6 Viking model parachutes for equivalent fabric materials and test conditions. This was attributed to the MPF model parachutes larger band height to nominal diameter ratio. For both designs, model parachutes fabricated from F-111 fabric had significantly greater statically stable absolute trim angles of attack at equivalent test conditions as compared to those fabricated from MILC-7020 Type III fabric. This reduction in static stability exhibited by model parachutes fabricated from F-111 fabric was attributed to the lower permeability of the F-111 fabric. The drag and static stability coefficient results were interpolated to obtain their values at Mars flight conditions using total porosity as the interpolating parameter.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Wind Tunnel Testing of Various Disk-Gap-Band Parachutes


    Beteiligte:

    Kongress:

    17th AIAA Aerodynamics Decelerator Systems Technology Conference ; 2003 ; Phoenix, AZ, United States


    Erscheinungsdatum :

    2003-01-01


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Wind Tunnel Testing of Various Disk-Gap-Band Parachutes

    Cruz, Juan / Mineck, Raymond / Keller, Donald et al. | AIAA | 2003


    Wind Tunnel Test of Subscale Ringsail and Disk-Gap-Band Parachutes

    Zumwalt, Carlie / Cruz, Juan / O'Farrell, Clara et al. | AIAA | 2016


    Wind Tunnel Test of Subscale Ringsail and Disk-Gap-Band Parachutes

    Zumwalt, Carlie H. / Cruz, Juan R. / Keller, Donald F. et al. | NTRS | 2016


    Wind Tunnel Test of Subscale Ringsail and Disk-Gap-Band Parachutes

    C. H. Zumwalt / J. R. Cruz / D. F. Keller et al. | NTIS | 2016


    Opening Loads Analyses for Various Disk-Gap-Band Parachutes

    Cruz, J. R. / Kandis, M. / Witkowski, A. | NTRS | 2003