The purpose of this test was to evaluate the accuracy of the AN/USQ-35 (BIDOPS) Non-Cooperative Scoring System installation in the William Tell 1965 configured TDU-9/B aerial tow target. The accuracy data were obtained by conducting 21 firing missions over a precision ground optics range. Both infrared and radar guided missiles were launched from interceptor aircraft at altitudes from 11,000 to 13,800 feet MSL. The effective scoring range established for this BIDOPS/TDU-9/B target configuration was 0 to 20 feet. For all scores recorded by both optics and BIDOPS, BIDOPS was within + or -4 feet of the optical instrumentation used as a standard.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Accuracy Test of the AN/DSQ-7 (Bidops) Scorer Installed in the Tdu-9/B TOW Target


    Beteiligte:
    J. C. Macon (Autor:in)

    Erscheinungsdatum :

    1966


    Format / Umfang :

    31 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch






    Frictional drag test apparatus installed in cavitation tunnel

    SO WON JEONG / BU GEUN PAIK / KYOUNG YOUL KIM | Europäisches Patentamt | 2023

    Freier Zugriff


    Frictional drag test apparatus installed in cavitation tunnel

    Europäisches Patentamt | 2024

    Freier Zugriff