Direct reconstruction of parametric images from raw photon counts has been shown to improve the quantitative analysis of dynamic positron emission tomography (PET) data. However it suffers from subject motion which is inevitable during the typical acquisition time of 1-2 hours. In this work we propose a framework to jointly estimate subject head motion and reconstruct the motion-corrected parametric images directly from raw PET data, so that the effects of distorted tissue-to-voxel mapping due to subject motion can be reduced in reconstructing the parametric images with motion-compensated attenuation correction and spatially aligned temporal PET data. The proposed approach is formulated within the maximum likelihood framework, and efficient solutions are derived for estimating subject motion and kinetic parameters from raw PET photon count data. Results from evaluations on simulated [11C]raclopride data using the Zubal brain phantom and real clinical [18F]florbetapir data of a patient with Alzheimer’s disease show that the proposed joint direct parametric reconstruction motion correction approach can improve the accuracy of quantifying dynamic PET data with large subject motion.


    Zugriff

    Download


    Exportieren, teilen und zitieren



    Titel :

    Direct parametric reconstruction with joint motion estimation/correction for dynamic brain PET data


    Beteiligte:
    Jiao, J (Autor:in) / Boss, A (Autor:in) / Thielemans, K (Autor:in) / Burgos, N (Autor:in) / Weston, P (Autor:in) / Markiewicz, P (Autor:in) / Schott, J (Autor:in) / Atkinson, D (Autor:in) / Arridge, S (Autor:in) / Hutton, B (Autor:in)

    Erscheinungsdatum :

    2016-08-24


    Anmerkungen:

    IEEE Transactions on Medical Imaging , 36 (1) (2016)


    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Klassifikation :

    DDC:    629



    Generalized least squares-based parametric motion estimation

    Montoliu, R. / Pla, F. | British Library Online Contents | 2009



    Joint PET-MR respiratory motion models for clinical PET motion correction

    Manber, R / Thielemans, K / Hutton, BF et al. | BASE | 2016

    Freier Zugriff

    Joint estimation of motion parameters using Newton's method

    Zhenmiao Deng, / Maozhong Fu, / Sheng Jin, et al. | IEEE | 2015


    Tissue Motion Estimation and Correction in Super Resolution Imaging

    Jensen, Jorgen Arendt / Andersen, Sofie B. / Villagomez Hoyos, Carlos A. et al. | BASE | 2019

    Freier Zugriff