As near-infrared spectroscopy (NIRS) broadens its application area to different age and disease groups, motion artifacts in the NIRS signal due to subject movement is becoming an important challenge. Motion artifacts generally produce signal fluctuations that are larger than physiological NIRS signals, thus it is crucial to correct for them before obtaining an estimate of stimulus evoked hemodynamic responses. There are various methods for correction such as principle component analysis (PCA), wavelet-based filtering and spline interpolation. Here, we introduce a new approach to motion artifact correction, targeted principle component analysis (tPCA), which incorporates a PCA filter only on the segments of data identified as motion artifacts. It is expected that this will overcome the issues of filtering desired signals that plagues standard PCA filtering of entire data sets. We compared the new approach with the most effective motion artifact correction algorithms on a set of data acquired simultaneously with a collodion-fixed probe (low motion artifact content) and a standard Velcro probe (high motion artifact content). Our results show that tPCA gives statistically better results in recovering hemodynamic response function (HRF) as compared to wavelet-based filtering and spline interpolation for the Velcro probe. It results in a significant reduction in mean-squared error (MSE) and significant enhancement in Pearson's correlation coefficient to the true HRF. The collodion-fixed fiber probe with no motion correction performed better than the Velcro probe corrected for motion artifacts in terms of MSE and Pearson's correlation coefficient. Thus, if the experimental study permits, the use of a collodion-fixed fiber probe may be desirable. If the use of a collodion-fixed probe is not feasible, then we suggest the use of tPCA in the processing of motion artifact contaminated data. ; P41 EB015896 - NIBIB NIH HHS; P41 RR014075 - NCRR NIH HHS; R01 GM104986 - NIGMS NIH HHS ; https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4211632/ ; Accepted manuscript ; Published version


    Zugriff

    Download


    Exportieren, teilen und zitieren



    Titel :

    Targeted principle component analysis: a new motion artifact correction approach for near-infrared spectroscopy


    Beteiligte:
    Yücel, Meryem A. (Autor:in) / Selb, Juliette (Autor:in) / Cooper, Robert J. (Autor:in) / Boas, David A. (Autor:in)

    Erscheinungsdatum :

    2014-03-01


    Anmerkungen:

    241794



    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Klassifikation :

    DDC:    629




    Motion Artifact Reduction in Breast Dynamic Infrared Imaging

    AGOSTINI, VALENTINA / KNAFLITZ, Marco / MOLINARI, FILIPPO | BASE | 2009

    Freier Zugriff

    Support-constrained motion-artifact correction for magnetic resonance imaging

    Fienup, J. R. / Van Buhler, J. E. / Optical Society of America | British Library Conference Proceedings | 1995


    Motion Artifact Correction of MRI Via Iterative Inverse Problem Solving

    Tseng, Y.-H. / Hwang, J.-N. / Yuan, C. et al. | British Library Conference Proceedings | 1994


    Systems and methods for providing image motion artifact correction for a color sequential (CS) display

    FYE JAMES / SUDDRETH JOHN / LEIPHON KENNETH et al. | Europäisches Patentamt | 2023

    Freier Zugriff

    SYSTEMS AND METHODS FOR PROVIDING IMAGE MOTION ARTIFACT CORRECTION FOR A COLOR SEQUENTIAL (CS) DISPLAY

    FYE JAMES / SUDDRETH JOHN / LEIPHON KENNETH et al. | Europäisches Patentamt | 2023

    Freier Zugriff